Thermal Fuses L50N.G902
Version Data
- Name
- L50N G902
- Version
- radial
- Max current (A)
- 5/10/20/25
- Temperature (C)
- 72 - 184
- Tolerance (K)
- +0 / -5
| Tf (C) |
| 072 |
| 077 |
| 084 |
| 093 |
| 098 |
| 100 |
| 104 |
| 110 |
| 117 |
| 121 |
| 128 |
| 144 |
| 152 |
| 167 |
| 172 |
| 184 |
| 190 |
| 192 |
| 205 |
| 216 |
| 229 |
| 240 |
| Tc (C) |
| 057 |
| 062 |
| 069 |
| 078 |
| 083 |
| 085 |
| 089 |
| 095 |
| 102 |
| 106 |
| 113 |
| 129 |
| 137 |
| 152 |
| 157 |
| 169 |
| 175 |
| 177 |
| 189 |
| 200 |
| 200 |
| 200 |
| Tm (C) |
| 100 |
| 125 |
| 125 |
| 140 |
| 140 |
| 140 |
| 150 |
| 150 |
| 160 |
| 160 |
| 205 |
| 240 |
| 205 |
| 240 |
| 240 |
| 210 |
| 310 |
| 210 |
| 310 |
| 375 |
| 375 |
| 450 |
technical description:
- metal housing
- standard lead length (mm): 240 +/-10
- Tf = functioning open temperature
- Tc = holding temperature: max. continuous exposure temperature during operation
- Tm = max. overshoot temperature: above this temperature the TCO might conduct again