Thermal Fuses MTS1
Version Data
- Name
- MTS1
- Version
- radial
- Max current (A)
- 5
- Temperature (C)
- 100 - 143
- Tolerance (K)
- +0 / -10
Tf (C) |
100 |
110 |
130 |
143 |
Tc (C) |
070 |
080 |
100 |
110 |
Tm (C) |
180 |
180 |
180 |
180 |
technical description:
- plastic housing
- lead length (mm): 50
- Ø wire (mm): 0.70
- Tf = functioning open temperature
- Tc = holding temperature: max. continuous exposure temperature during operation
- Tm = max. overshoot temperature: above this temperature the TCO might conduct again