Thermal Fuses MTTF
Version Data
- Name
- MTTF
- Version
- Axial
- Max current (A)
- 1/2
- Temperature (C)
- 65 - 139
- Tolerance (K)
- +0 / -10
| Tf (C) |
| 065 |
| 076 |
| 086 |
| 102 |
| 115 |
| 127 |
| 133 |
| 136 |
| 139 |
| Tc (C) |
| 050 |
| 055 |
| 060 |
| 075 |
| 095 |
| 110 |
| 105 |
| 105 |
| 120 |
| Tm (C) |
| 200 |
| 200 |
| 200 |
| 200 |
| 200 |
| 200 |
| 200 |
| 200 |
| 200 |
technical description:
- ceramic housing
- standard lead length (mm): 68/68 (long/long)
- lead length (mm): 38/38 (short/short)
- Ø wire (mm): 0.53
- Tf = functioning open temperature
- Tc = holding temperature: max. continuous exposure temperature during operation
- Tm = max. overshoot temperature: above this temperature the TCO might conduct again