Thermal Fuses MTTF
Version Data
- Name
- MTTF
- Version
- Axial
- Max current (A)
- 1/2
- Temperature (C)
- 65 - 139
- Tolerance (K)
- +0 / -10
Tf (C) |
065 |
076 |
086 |
102 |
115 |
127 |
133 |
136 |
139 |
Tc (C) |
050 |
055 |
060 |
075 |
095 |
110 |
105 |
105 |
120 |
Tm (C) |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
200 |
technical description:
- ceramic housing
- standard lead length (mm): 68/68 (long/long)
- lead length (mm): 38/38 (short/short)
- Ø wire (mm): 0.53
- Tf = functioning open temperature
- Tc = holding temperature: max. continuous exposure temperature during operation
- Tm = max. overshoot temperature: above this temperature the TCO might conduct again