Thermal Fuses S3M7
Version Data
- Name
- S3M7
- Version
- Axial
- Max current (A)
- 5
- Temperature (C)
- 70 - 190°C
- Tolerance (K)
- +0 / -10
| Tf (C) |
| 070 |
| 077 |
| 084 |
| 093 |
| 098 |
| 100 |
| 110 |
| 117 |
| 121 |
| 128 |
| 144 |
| 152 |
| 167 |
| 172 |
| 184 |
| 190 |
| Tc (C) |
| 055 |
| 062 |
| 069 |
| 078 |
| 83 |
| 85 |
| 095 |
| 102 |
| 106 |
| 113 |
| 129 |
| 137 |
| 152 |
| 157 |
| 169 |
| 175 |
| Tm (C) |
| 125 |
| 125 |
| 125 |
| 140 |
| 140 |
| 130 |
| 140 |
| 150 |
| 150 |
| 150 |
| 175 |
| 175 |
| 200 |
| 200 |
| 200 |
| 270 |
technical description:
- metal housing
- lead length (mm): 35/35 (long/long)
- Ø wire (mm): 0.57
- Tf = functioning open temperature
- Tc = holding temperature: max. continuous exposure temperature during operation
- Tm = max. overshoot temperature: above this temperature the TCO might conduct again