Thermal Fuses S3M7
Version Data
- Name
- S3M7
- Version
- Axial
- Max current (A)
- 5
- Temperature (C)
- 70 - 190°C
- Tolerance (K)
- +0 / -10
Tf (C) |
070 |
077 |
084 |
093 |
098 |
100 |
110 |
117 |
121 |
128 |
144 |
152 |
167 |
172 |
184 |
190 |
Tc (C) |
055 |
062 |
069 |
078 |
83 |
85 |
095 |
102 |
106 |
113 |
129 |
137 |
152 |
157 |
169 |
175 |
Tm (C) |
125 |
125 |
125 |
140 |
140 |
130 |
140 |
150 |
150 |
150 |
175 |
175 |
200 |
200 |
200 |
270 |
technical description:
- metal housing
- lead length (mm): 35/35 (long/long)
- Ø wire (mm): 0.57
- Tf = functioning open temperature
- Tc = holding temperature: max. continuous exposure temperature during operation
- Tm = max. overshoot temperature: above this temperature the TCO might conduct again