Thermal Fuses S3M8
Version Data
- Name
- S3M8
- Version
- Axial
- Max current (A)
- 25
- Temperature (C)
- 70 - 240
- Tolerance (K)
- +0 / -10
| Tf (C) |
| 070 |
| 072 |
| 077 |
| 084 |
| 093 |
| 098 |
| 104 |
| 110 |
| 117 |
| 121 |
| 128 |
| 144 |
| 152 |
| 167 |
| 184 |
| 192 |
| 229 |
| 240 |
| Tc (C) |
| 045 |
| 047 |
| 052 |
| 059 |
| 068 |
| 073 |
| 079 |
| 085 |
| 092 |
| 096 |
| 103 |
| 119 |
| 127 |
| 142 |
| 159 |
| 167 |
| 200 |
| 200 |
| Tm (C) |
| 175 |
| 175 |
| 200 |
| 200 |
| 215 |
| 215 |
| 225 |
| 225 |
| 235 |
| 235 |
| 235 |
| 250 |
| 250 |
| 285 |
| 350 |
| 350 |
| 375 |
| 375 |
technical description:
- metal housing
- standard lead length (mm): 16/35 (short/long)
- lead length (mm): 35/35 (long/long)
- Ø wire (mm): 1.0
- Tf = functioning open temperature
- Tc = holding temperature: max. continuous exposure temperature during operation
- Tm = max. overshoot temperature: above this temperature the TCO might conduct again